Browse Source
I had a ledger nano S and a ledger nano S plus connected at the same time, and the "id_"s were colliding resulting in weird behaviour. Multisig was pretty much not usable with both devices connected simultaneously. Example dicts returned by `hid.enumerate(0, 0)`: {'path': b'\\\\?\\hid#vid_2c97&pid_1015&mi_00#a&2a30{REDACTED}&0&0000#{REDACTED_UUID}', 'vendor_id': 11415, 'product_id': 4117, 'serial_number': '0001', 'release_number': 513, 'manufacturer_string': 'Ledger', 'product_string': 'Nano S', 'usage_page': 65440, 'usage': 1, 'interface_number': 0}, {'path': b'\\\\?\\hid#vid_2c97&pid_5011&mi_00#a&28d{REDACTED}&0&0000#{REDACTED_UUID}', 'vendor_id': 11415, 'product_id': 20497, 'serial_number': '0001', 'release_number': 513, 'manufacturer_string': 'Ledger', 'product_string': 'Nano S Plus', 'usage_page': 65440, 'usage': 1, 'interface_number': 0}patch-4
1 changed files with 5 additions and 4 deletions