You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

215 lines
5.4 KiB

io.js
===
[![Gitter](https://badges.gitter.im/Join Chat.svg)](https://gitter.im/iojs/io.js?utm_source=badge&utm_medium=badge&utm_campaign=pr-badge&utm_content=badge)
This repository began as a GitHub fork of
[joyent/node](https://github.com/joyent/node).
io.js contributions, releases, and contributorship are under an
[open governance model](./GOVERNANCE.md).
We intend to land, with increasing regularity, releases which are
compatible with the npm ecosystem that has been built to date for Node.js.
## Is it io.js or IO.js or iojs or IOjs or iOjS?
The official name is **io.js**, which should never be capitalized,
especially not at the start of a sentence, unless it is being
displayed in a location that is customarily all-caps (such as
the title of man pages).
## To build:
### Unix / Macintosh
Prerequisites:
* `gcc` and `g++` 4.8 or newer, or
* `clang` and `clang++` 3.3 or newer
* Python 2.6 or 2.7
* GNU Make 3.81 or newer
* libexecinfo (FreeBSD and OpenBSD only)
```text
$ ./configure
$ make
$ make install
```
If your Python binary is in a non-standard location or has a
non-standard name, run the following instead:
```text
$ export PYTHON=/path/to/python
$ $PYTHON ./configure
$ make
$ make install
```
To run the tests:
```text
$ make test
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```
To build the documentation:
```text
$ make doc
```
To read the documentation:
```text
$ man doc/iojs.1
```
### Windows
Prerequisites:
* [Python 2.6 or 2.7](https://www.python.org/downloads/)
* Visual Studio 2013 for Windows Desktop, or
* Visual Studio Express 2013 for Windows Desktop
* Basic Unix tools required for some tests,
[Git for Windows](http://git-scm.com/download/win) includes Git Bash
and tools which can be included in the global `PATH`.
```text
> vcbuild nosign
```
To run the tests:
```text
> vcbuild test
```
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
### `Intl` (ECMA-402) support:
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
[Intl](https://github.com/joyent/node/wiki/Intl) support is not
enabled by default.
#### "small" (English only) support
This option will build with "small" (English only) support, but
the full `Intl` (ECMA-402) APIs. With `--download=all` it will
download the ICU library as needed.
Unix / Macintosh:
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```text
$ ./configure --with-intl=small-icu --download=all
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
Windows:
```text
> vcbuild small-icu download-all
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
The `small-icu` mode builds with English-only data. You can add full
data at runtime.
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
*Note:* more docs are on
[the joyent/node wiki](https://github.com/joyent/node/wiki/Intl).
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
#### Build with full ICU support (all locales supported by ICU):
With the `--download=all`, this may download ICU if you don't have an
ICU in `deps/icu`.
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
Unix / Macintosh:
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```text
$ ./configure --with-intl=full-icu --download=all
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
Windows:
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```text
> vcbuild full-icu download-all
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
#### Build with no Intl support `:-(`
The `Intl` object will not be available. This is the default at
present, so this option is not normally needed.
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
Unix / Macintosh:
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```text
$ ./configure --with-intl=none
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
```
Windows:
```text
> vcbuild intl-none
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
#### Use existing installed ICU (Unix / Macintosh only):
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```text
$ pkg-config --modversion icu-i18n && ./configure --with-intl=system-icu
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
#### Build with a specific ICU:
You can find other ICU releases at
[the ICU homepage](http://icu-project.org/download).
Download the file named something like `icu4c-**##.#**-src.tgz` (or
`.zip`).
Unix / Macintosh
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```text
# from an already-unpacked ICU:
$ ./configure --with-intl=[small-icu,full-icu] --with-icu-source=/path/to/icu
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
# from a local ICU tarball
$ ./configure --with-intl=[small-icu,full-icu] --with-icu-source=/path/to/icu.tgz
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
# from a tarball URL
$ ./configure --with-intl=full-icu --with-icu-source=http://url/to/icu.tgz
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
Windows
First unpack latest ICU to `deps/icu`
[icu4c-**##.#**-src.tgz](http://icu-project.org/download) (or `.zip`)
as `deps/icu` (You'll have: `deps/icu/source/...`)
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```text
> vcbuild full-icu
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
```
## Resources for Newcomers
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
* [CONTRIBUTING.md](./CONTRIBUTING.md)
* [GOVERNANCE.md](./GOVERNANCE.md)
* IRC:
[#io.js on Freenode.net](http://webchat.freenode.net?channels=io.js&uio=d4)
* [iojs/io.js on Gitter](https://gitter.im/iojs/io.js)
## Current Project Team Members
The io.js project team comprises a group of core collaborators and a sub-group
that forms the _Technical Committee_ (TC) which governs the project. For more
information about the governance of the io.js project, see
[GOVERNANCE.md](./GOVERNANCE.md).
* **Isaac Z. Schlueter** ([@isaacs](https://github.com/isaacs)) <i@izs.me> (Technical Committee)
* **Ben Noordhuis** ([@bnoordhuis](https://github.com/bnoordhuis)) <info@bnoordhuis.nl> (Technical Committee)
* **Bert Belder** ([@piscisaureus](https://github.com/piscisaureus)) <bertbelder@gmail.com> (Technical Committee)
* **Fedor Indutny** ([@indutny](https://github.com/indutny)) <fedor.indutny@gmail.com> (Technical Committee)
* **Trevor Norris** ([@trevnorris](https://github.com/trevnorris)) <trev.norris@gmail.com> (Technical Committee)
* **Chris Dickinson** ([@chrisdickinson](https://github.com/chrisdickinson)) <christopher.s.dickinson@gmail.com> (Technical Committee)
* **Colin Ihrig** ([@cjihrig](https://github.com/cjihrig)) <cjihrig@gmail.com> (Technical Committee)
* **Mikeal Rogers** ([@mikeal](https://github.com/mikeal)) <mikeal.rogers@gmail.com>
* **Rod Vagg** ([@rvagg](https://github.com/rvagg)) <rod@vagg.org>
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
Collaborators follow the [COLLABORATOR_GUIDE.md](./COLLABORATOR_GUIDE.md) in
maintaining the io.js project.