Browse Source

monitor temp

master
Christian Rotzoll 6 years ago
parent
commit
5192165bb9
  1. 11
      home.admin/config.scripts/blitz.powertest.sh

11
home.admin/config.scripts/blitz.powertest.sh

@ -38,13 +38,16 @@ for (( n=0; n<15; ++n )); do
voltInt=${voltFloat/.*}
echo "V -> ${voltFloat}/${voltInt}"
if [ ${voltInt} -lt 12500 ]; then
echo "Voltage too low"
else
echo "Voltage OK"
echo "Voltage too Low" >&2
fi
# analyse Temp
echo "T -> ${Temp/\'C/}"
tempFloat=$(echo "${Temp/\'C/}*100" | bc)
tempInt=${tempFloat/.*}
echo "T -> ${tempFloat}/${tempInt}"
if [ ${voltInt} -gt 6999 ]; then
echo "Temp too High" >&2
fi
sleep 5
done
Loading…
Cancel
Save