You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.

223 lines
7.4 KiB

@echo off
cd %~dp0
if /i "%1"=="help" goto help
if /i "%1"=="--help" goto help
if /i "%1"=="-help" goto help
if /i "%1"=="/help" goto help
if /i "%1"=="?" goto help
if /i "%1"=="-?" goto help
if /i "%1"=="--?" goto help
if /i "%1"=="/?" goto help
@rem Process arguments.
set config=Release
set msiplatform=x86
set target=Build
set target_arch=ia32
set debug_arg=
set snapshot_arg=
set noprojgen=
set nobuild=
set nosign=
set snapshot=
set test=
set test_args=
set msi=
set licensertf=
set jslint=
set buildnodeweak=
set noetw=
set noetw_arg=
set noetw_msi_arg=
set noperfctr=
set noperfctr_arg=
set noperfctr_msi_arg=
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
set i18n_arg=
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
set download_arg=
:next-arg
if "%1"=="" goto args-done
if /i "%1"=="debug" set config=Debug&goto arg-ok
if /i "%1"=="release" set config=Release&goto arg-ok
if /i "%1"=="clean" set target=Clean&goto arg-ok
if /i "%1"=="ia32" set target_arch=ia32&goto arg-ok
if /i "%1"=="x86" set target_arch=ia32&goto arg-ok
if /i "%1"=="x64" set target_arch=x64&goto arg-ok
if /i "%1"=="noprojgen" set noprojgen=1&goto arg-ok
if /i "%1"=="nobuild" set nobuild=1&goto arg-ok
if /i "%1"=="nosign" set nosign=1&goto arg-ok
if /i "%1"=="snapshot" set snapshot=1&goto arg-ok
if /i "%1"=="noetw" set noetw=1&goto arg-ok
if /i "%1"=="noperfctr" set noperfctr=1&goto arg-ok
if /i "%1"=="licensertf" set licensertf=1&goto arg-ok
if /i "%1"=="test-uv" set test=test-uv&goto arg-ok
if /i "%1"=="test-internet" set test=test-internet&goto arg-ok
if /i "%1"=="test-pummel" set test=test-pummel&goto arg-ok
if /i "%1"=="test-simple" set test=test-simple&goto arg-ok
if /i "%1"=="test-message" set test=test-message&goto arg-ok
if /i "%1"=="test-gc" set test=test-gc&set buildnodeweak=1&goto arg-ok
if /i "%1"=="test-all" set test=test-all&set buildnodeweak=1&goto arg-ok
if /i "%1"=="test" set test=test&goto arg-ok
if /i "%1"=="msi" set msi=1&set licensertf=1&goto arg-ok
if /i "%1"=="jslint" set jslint=1&goto arg-ok
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
if /i "%1"=="small-icu" set i18n_arg=%1&goto arg-ok
if /i "%1"=="full-icu" set i18n_arg=%1&goto arg-ok
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
if /i "%1"=="intl-none" set i18n_arg=%1&goto arg-ok
if /i "%1"=="download-all" set download_arg="--download=all"&goto arg-ok
echo Warning: ignoring invalid command line option `%1`.
:arg-ok
:arg-ok
shift
goto next-arg
:args-done
if defined jslint goto jslint
if "%config%"=="Debug" set debug_arg=--debug
if "%target_arch%"=="x64" set msiplatform=x64
if defined snapshot set snapshot_arg=--with-snapshot
if defined noetw set noetw_arg=--without-etw& set noetw_msi_arg=/p:NoETW=1
if defined noperfctr set noperfctr_arg=--without-perfctr& set noperfctr_msi_arg=/p:NoPerfCtr=1
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
if "%i18n_arg%"=="full-icu" set i18n_arg=--with-intl=full-icu
if "%i18n_arg%"=="small-icu" set i18n_arg=--with-intl=small-icu
build: i18n: add icu config options Make "--with-intl=none" the default and add "intl-none" option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There's a "list" of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -> sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option "--with-icu-source=..." Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option "--with-icu-locals=...". Allows choosing which locales are used in the "small-icu" case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don't use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, "out" is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test's whitespace and logic] Signed-off-by: Trevor Norris <trev.norris@gmail.com>
10 years ago
if "%i18n_arg%"=="intl-none" set i18n_arg=--with-intl=none
build, i18n: improve Intl build, add "--with-intl" The two main goals of this change are: - To make it easier to build the Intl option using ICU (particularly, using a newer ICU than v8/Chromium's version) - To enable a much smaller ICU build with only English support The goal here is to get node.js binaries built this way by default so that the Intl API can be used. Additional data can be added at execution time (see Readme and wiki) More details are at https://github.com/joyent/node/pull/7719 In particular, this change adds the "--with-intl=" configure option to provide more ways of building "Intl": - "full-icu" picks up an ICU from deps/icu - "small-icu" is similar, but builds only English - "system-icu" uses pkg-config to find an installed ICU - "none" does nothing (no Intl) For Windows builds, the "full-icu" or "small-icu" options are added to vcbuild.bat. Note that the existing "--with-icu-path" option is not removed from configure, but may not be used alongside the new option. Wiki changes have already been made on https://github.com/joyent/node/wiki/Installation and a new page created at https://github.com/joyent/node/wiki/Intl (marked as provisional until this change lands.) Summary of changes: * README.md : doc updates * .gitignore : added "deps/icu" as this is the location where ICU is unpacked to. * Makefile : added the tools/icu/* files to cpplint, but excluded a problematic file. * configure : added the "--with-intl" option mentioned above. Calculate at config time the list of ICU source files to use and data packaging options. * node.gyp : add the new files src/node_i18n.cc/.h as well as ICU linkage. * src/node.cc : add call into node::i18n::InitializeICUDirectory(icu_data_dir) as well as new --icu-data-dir option and NODE_ICU_DATA env variable to configure ICU data loading. This loading is only relevant in the "small" configuration. * src/node_i18n.cc : new source file for the above Initialize.. function, to setup ICU as needed. * tools/icu : new directory with some tools needed for this build. * tools/icu/icu-generic.gyp : new .gyp file that builds ICU in some new ways, both on unix/mac and windows. * tools/icu/icu-system.gyp : new .gyp file to build node against a pkg-config detected ICU. * tools/icu/icu_small.json : new config file for the "English-only" small build. * tools/icu/icutrim.py : new tool for trimming down ICU data. Reads the above .json file. * tools/icu/iculslocs.cc : new tool for repairing ICU data manifests after trim operation. * tools/icu/no-op.cc : dummy file to force .gyp into using a C++ linker. * vcbuild.bat : added small-icu and full-icu options, to call into configure. * Fixed toolset dependencies, see https://github.com/joyent/node/pull/7719#issuecomment-54641687 Note that because of a bug in gyp {CC,CXX}_host must also be set. Otherwise gcc/g++ will be used by default for part of the build. Reviewed-by: Trevor Norris <trev.norris@gmail.com> Reviewed-by: Fedor Indutny <fedor@indutny.com>
10 years ago
:project-gen
@rem Skip project generation if requested.
if defined noprojgen goto msbuild
if defined NIGHTLY set TAG=nightly-%NIGHTLY%
@rem Generate the VS project.
SETLOCAL
if defined VS100COMNTOOLS call "%VS100COMNTOOLS%\VCVarsQueryRegistry.bat"
python configure %download_arg% %i18n_arg% %debug_arg% %snapshot_arg% %noetw_arg% %noperfctr_arg% --dest-cpu=%target_arch% --tag=%TAG%
if errorlevel 1 goto create-msvs-files-failed
if not exist node.sln goto create-msvs-files-failed
echo Project files generated.
ENDLOCAL
:msbuild
@rem Skip project generation if requested.
if defined nobuild goto sign
@rem Look for Visual Studio 2013
if not defined VS120COMNTOOLS goto msbuild-not-found
if not exist "%VS120COMNTOOLS%\..\..\vc\vcvarsall.bat" goto msbuild-not-found
if "%VCVARS_VER%" NEQ "120" (
call "%VS120COMNTOOLS%\..\..\vc\vcvarsall.bat"
SET VCVARS_VER=120
)
if not defined VCINSTALLDIR goto msbuild-not-found
set GYP_MSVS_VERSION=2013
goto msbuild-found
:msbuild-not-found
echo Build skipped. To build, this file needs to run from VS cmd prompt.
goto run
:msbuild-found
@rem Build the sln with msbuild.
msbuild node.sln /m /t:%target% /p:Configuration=%config% /clp:NoSummary;NoItemAndPropertyList;Verbosity=minimal /nologo
if errorlevel 1 goto exit
:sign
@rem Skip signing if the `nosign` option was specified.
if defined nosign goto licensertf
signtool sign /a /d "io.js" /t http://timestamp.globalsign.com/scripts/timestamp.dll Release\iojs.exe
if errorlevel 1 echo Failed to sign exe&goto exit
:licensertf
@rem Skip license.rtf generation if not requested.
if not defined licensertf goto msi
%config%\iojs tools\license2rtf.js < LICENSE > %config%\license.rtf
if errorlevel 1 echo Failed to generate license.rtf&goto exit
:msi
@rem Skip msi generation if not requested
if not defined msi goto run
call :getnodeversion
if not defined NIGHTLY goto msibuild
set NODE_VERSION=%NODE_VERSION%.%NIGHTLY%
:msibuild
echo Building iojs-%NODE_VERSION%
msbuild "%~dp0tools\msvs\msi\nodemsi.sln" /m /t:Clean,Build /p:Configuration=%config% /p:Platform=%msiplatform% /p:NodeVersion=%NODE_VERSION% %noetw_msi_arg% %noperfctr_msi_arg% /clp:NoSummary;NoItemAndPropertyList;Verbosity=minimal /nologo
if errorlevel 1 goto exit
if defined nosign goto run
signtool sign /a /d "io.js" /t http://timestamp.globalsign.com/scripts/timestamp.dll Release\iojs-v%NODE_VERSION%-%msiplatform%.msi
if errorlevel 1 echo Failed to sign msi&goto exit
:run
@rem Run tests if requested.
if "%test%"=="" goto exit
if "%config%"=="Debug" set test_args=--mode=debug
if "%config%"=="Release" set test_args=--mode=release
if "%test%"=="test" set test_args=%test_args% sequential parallel message -J
if "%test%"=="test-internet" set test_args=%test_args% internet
if "%test%"=="test-pummel" set test_args=%test_args% pummel
if "%test%"=="test-simple" set test_args=%test_args% sequential parallel
if "%test%"=="test-message" set test_args=%test_args% message
if "%test%"=="test-gc" set test_args=%test_args% gc
if "%test%"=="test-all" set test_args=%test_args%
:build-node-weak
@rem Build node-weak if required
if "%buildnodeweak%"=="" goto run-tests
"%config%\node" deps\npm\node_modules\node-gyp\bin\node-gyp rebuild --directory="%~dp0test\gc\node_modules\weak" --nodedir="%~dp0."
if errorlevel 1 goto build-node-weak-failed
goto run-tests
:build-node-weak-failed
echo Failed to build node-weak.
goto exit
:run-tests
echo running 'python tools/test.py %test_args%'
python tools/test.py %test_args%
if "%test%"=="test" goto jslint
goto exit
:create-msvs-files-failed
echo Failed to create vc project files.
goto exit
:jslint
echo running jslint
set PYTHONPATH=tools/closure_linter/;tools/gflags/
python tools/closure_linter/closure_linter/gjslint.py --unix_mode --strict --nojsdoc -r lib/ -r src/ --exclude_files lib/punycode.js
goto exit
:help
build: i18n: add icu config options Make &#34;--with-intl=none&#34; the default and add &#34;intl-none&#34; option to vcbuild.bat. If icu data is missing print a warning unless either --download=all or --download=icu is set. If set then automatically download, verify (MD5) and unpack the ICU data if not already available. There&#39;s a &#34;list&#34; of URLs being used, but right now only the first is picked up. The logic works something like this: * If there is no directory deps/icu, * If no zip file (currently icu4c-54_1-src.zip), * Download zip file (icu-project.org -&gt; sf.net) * Verify the MD5 sum of the zipfile * If bad, print error and exit * Unpack the zipfile into deps/icu * If deps/icu now exists, use it, else fail with help text Add the configuration option &#34;--with-icu-source=...&#34; Usage: * --with-icu-source=/path/to/my/other/icu * --with-icu-source=/path/to/icu54.zip * --with-icu-source=/path/to/icu54.tgz * --with-icu-source=http://example.com/icu54.tar.bz2 Add the configuration option &#34;--with-icu-locals=...&#34;. Allows choosing which locales are used in the &#34;small-icu&#34; case. Example: configure --with-intl=small-icu --with-icu-locales=tlh,grc,nl (Also note that as of this writing, neither Klingon nor Ancient Greek are in upstream CLDR data. Serving suggestion only.) Don&#39;t use hard coded ../../out paths on windows. This was suggested by @misterdjules as it causes test failures. With this fix, &#34;out&#34; is no longer created on windows and the following can run properly: python tools/test.py simple Reduce space by about 1MB with ICU 54 (over without this patch). Also trims a few other source files, but only conditional on the exact ICU version used. This is to future-proof - a file that is unneeded now may be needed in future ICUs. Also: * Update distclean to remove icu related files * Refactor some code into tools/configure.d/nodedownload.py * Update docs * Add test PR-URL: https://github.com/joyent/node/pull/8719 Fixes: https://github.com/joyent/node/issues/7676#issuecomment-64704230 [trev.norris@gmail.com small change to test&#39;s whitespace and logic] Signed-off-by: Trevor Norris &lt;trev.norris@gmail.com&gt;
10 years ago
echo vcbuild.bat [debug/release] [msi] [test-all/test-uv/test-internet/test-pummel/test-simple/test-message] [clean] [noprojgen] [small-icu/full-icu/intl-none] [nobuild] [nosign] [x86/x64] [download-all]
echo Examples:
echo vcbuild.bat : builds release build
echo vcbuild.bat debug : builds debug build
echo vcbuild.bat release msi : builds release build and MSI installer package
echo vcbuild.bat test : builds debug build and runs tests
goto exit
:exit
goto :EOF
rem ***************
rem Subroutines
rem ***************
:getnodeversion
set NODE_VERSION=
for /F "usebackq tokens=*" %%i in (`python "%~dp0tools\getnodeversion.py"`) do set NODE_VERSION=%%i
if not defined NODE_VERSION echo Cannot determine current version of io.js & exit /b 1
goto :EOF