  1. 6
      home.admin/config.scripts/blitz.powertest.sh

6
home.admin/config.scripts/blitz.powertest.sh

@ -36,7 +36,7 @@ for (( n=0; n<15; ++n )); do
# analyse Voltage
voltFloat=$(echo "${CoreVoltage/V/}*10000" | bc)
voltInt=${voltFloat/.*}
echo "V -> ${voltFloat}/${voltInt}"
#echo "V -> ${voltFloat}/${voltInt}"
if [ ${voltInt} -lt 12500 ]; then
echo "Voltage too Low" >&2
fi
@ -44,8 +44,8 @@ for (( n=0; n<15; ++n )); do
# analyse Temp
tempFloat=$(echo "${Temp/\'C/}*100" | bc)
tempInt=${tempFloat/.*}
echo "T -> ${tempFloat}/${tempInt}"
if [ ${voltInt} -gt 6999 ]; then
#echo "T -> ${tempFloat}/${tempInt}"
if [ ${tempInt} -gt 6999 ]; then
echo "Temp too High" >&2
fi